Smart Contact Lens Biosensor for Continuous Intraocular Pressure Monitoring in Glaucoma
DOI:
https://doi.org/10.5281/zenodo.22502679Keywords:
intraocular pressure monitoring, smart contact lens biosensor, glaucoma diagnostics, wireless telemetry sensor, continuous ophthalmic monitoringAbstract
Background: Glaucoma, the leading cause of irreversible blindness, is managed primarily through control of intraocular pressure (IOP), yet standard office tonometry captures only isolated daytime snapshots of a pressure signal that fluctuates continuously, often peaking overnight. Objective: This narrative review synthesizes published literature on smart contact lens biosensors developed to enable continuous, ambulatory IOP monitoring in glaucoma. Methods: We reviewed clinical and engineering studies of the commercially available Sensimed Triggerfish strain-gauge sensor and experimental microfabricated, resonant, and multifunctional contact lens platforms, focusing on transducer design, wireless telemetry, and clinical validation against reference tonometry. Findings: The Triggerfish sensor is safe and well tolerated across repeated 24-hour sessions and detects nocturnal IOP-related dynamics that correlate with visual field progression, though its dimensional output correlates imperfectly with absolute tonometric pressure. Emerging MEMS strain-gauge, resonant LC, and advanced wireless-readout designs report substantially improved sensitivity and, in some cases, quantitative pressure correlation in animal models. Conclusions: Contact lens biosensors have established continuous IOP profiling as clinically feasible, and next-generation sensing and telemetry architectures may extend this capability toward calibrated, multifunctional theranostic monitoring.
References
Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology, 121(11):2081-2090, DOI:10.1016/j.ophtha.2014.05.013.
Weinreb RN, Leung CKS, Crowston JG, Medeiros FA, Friedman DS, Wiggs JL, Martin KR (2016) Primary open-angle glaucoma. Nature Reviews Disease Primers, 2:16067, DOI:10.1038/nrdp.2016.67.
Kazemi A, McLaren JW, Sit AJ (2015) Continuous 24-hour monitoring of intraocular pressure: emerging technologies. Current Ophthalmology Reports, 3(2):58-66, DOI:10.1007/s40135-015-0066-8.
Dunbar GE, Shen BY, Aref AA (2017) The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient tolerability. Clinical Ophthalmology, 11:875-882, DOI:10.2147/OPTH.S109708.
Dou Z, Tang J, Liu Z, Sun Q, Wang Y, Li Y, Yuan M, Wu H, Wang Y, Pei W, Chen H (2021) A wearable contact lens sensor for noninvasive continuous monitoring of intraocular pressure. Micromachines, 12(2):108, DOI:10.3390/mi12020108.
Pang Y, Li Y, Wang X, Qi C, Yang Y, Ren TL (2019) A contact lens promising for non-invasive continuous intraocular pressure monitoring. RSC Advances, 9(9):5076-5082, DOI:10.1039/C8RA10257K.
An H, Wang X, Liao Z, Zhang L, Zhao H, Yang Y, Song J, Ma Y (2024) LC contact lens sensor for ultrasensitive intraocular pressure monitoring. npj Flexible Electronics, 8:53, DOI:10.1038/s41528-024-00341-z.
Xiao T, Zhang H, Takamatsu T, Ashimori A, Azhari S, Kimura K, Miyake T (2026) Ultra-sensitive real-time monitoring of intraocular pressure with an integrated smart contact lens using parity-time symmetry wireless technology. npj Flexible Electronics, 10:4, DOI:10.1038/s41528-025-00507-3.
Kim TY, Mok JW, Hong SH, Jeong SH, Choi H, Shin S, Joo CK, Hahn SK (2022) Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma. Nature Communications, 13:6801, DOI:10.1038/s41467-022-34597-8.
Liu W, Du Z, Duan Z, Li L, Shen G (2024) Neuroprosthetic contact lens enabled sensorimotor system for point-of-care monitoring and feedback of intraocular pressure. Nature Communications, 15:5635, DOI:10.1038/s41467-024-49907-5.
Mansouri K, Medeiros FA, Tafreshi A, Weinreb RN (2012) Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma. Archives of Ophthalmology, 130(12):1534-1539, DOI:10.1001/archophthalmol.2012.2280.
Mansouri K, Weinreb RN, Liu JHK (2015) Efficacy of a contact lens sensor for monitoring 24-h intraocular pressure related patterns. PLOS ONE, 10(5):e0125530, DOI:10.1371/journal.pone.0125530.
Liu JHK, Mansouri K, Weinreb RN (2015) Estimation of 24-hour intraocular pressure peak timing and variation using a contact lens sensor. PLOS ONE, 10(6):e0129529, DOI:10.1371/journal.pone.0129529.
De Moraes CG, Mansouri K, Liebmann JM, Ritch R (2018) Association between 24-hour intraocular pressure monitored with contact lens sensor and visual field progression in older adults with glaucoma. JAMA Ophthalmology, 136(7):779-785, DOI:10.1001/jamaophthalmol.2018.1746.
Higashide T, Udagawa S, Nakazawa K, Yamashita Y, Tsuchiya S, Ohkubo S, Sugiyama K (2024) Prediction of glaucoma progression by 24-h contact lens sensor profile in patients with normal-tension glaucoma. Scientific Reports, 14:21564, DOI:10.1038/s41598-024-72556-z.
Carnero E, Bragard J, Urrestarazu E, Rivas E, Polo V, Larrosa JM, Anton V, Pelaez A, Moreno-Montanes J (2020) Continuous intraocular pressure monitoring in patients with obstructive sleep apnea syndrome using a contact lens sensor. PLOS ONE, 15(3):e0229856, DOI:10.1371/journal.pone.0229856.
Chiou JC, Hsu SH, Huang YC, Yeh GT, Liou WT, Kuei CK (2017) A wirelessly powered smart contact lens with reconfigurable wide range and tunable sensitivity sensor readout circuitry. Sensors, 17(1):108, DOI:10.3390/s17010108.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Federica Russo, et al.

This work is licensed under a Creative Commons Attribution 4.0 International License.