Biomechanical Evaluation of a Novel Transcatheter Heart Valve Prototype in a Bench Model

Authors

DOI:

https://doi.org/10.5281/zenodo.22547655

Keywords:

transcatheter heart valve, bench testing, hydrodynamic performance, durability testing, paravalvular leak

Abstract

Background: Bench-model biomechanical evaluation is the mandatory first evidentiary tier for any novel transcatheter heart valve (THV) prototype, but reported methods and findings are scattered across a heterogeneous literature. Objective: This narrative review synthesizes real, peer-reviewed literature on how THV prototypes are evaluated at the bench, using the framing of a hypothetical novel prototype only as an organizing device. Methods: We reviewed published studies employing pulse-duplicator hydrodynamic testing, ISO 5840-3 accelerated wear and fatigue testing, leaflet stress analysis, and paravalvular leak models, covering prototypes such as TRISKELE, TRISKELION, Poli-Valve, DurAVR, and polymeric leaflet designs. Findings: Bench methods reliably differentiate designs on hydrodynamic efficiency, regurgitant fraction, and fatigue resistance, but reported performance is highly sensitive to test-rig anatomy, loading protocol, and comparator choice, and accelerated durability testing to hundreds of millions of cycles remains an imperfect surrogate for decades of physiological loading. Conclusions: ISO 5840-3 compliance provides a necessary but not sufficient baseline for clinical durability; anatomically representative, standardized bench models integrated with subsequent preclinical follow-up remain essential as new THV materials and geometries progress toward clinical use.

References

Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, Derumeaux G, Anselme F, Laborde F, Leon MB (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106(24):3006-3008. DOI:10.1161/01.CIR.0000047200.36165.B8

Wang Y, Fu Y, Wang Q, Kong D, Wang Z, Liu J (2024) Recent advancements in polymeric heart valves: From basic research to clinical trials. Materials Today Bio 28:101194. DOI:10.1016/j.mtbio.2024.101194

Buse EE, Hilbert SL, Hopkins RA, Converse GL (2016) Pulse Duplicator Hydrodynamic Testing of Bioengineered Biological Heart Valves. Cardiovascular Engineering and Technology 7(4):352-362. DOI:10.1007/s13239-016-0275-9

Ponnaluri SV, Sacks MS, Manning KB (2022) The Accelerated Transcatheter Heart Valve Testing Environment: Loading, Motion, and Fluid Dynamics. Journal of Biomechanical Engineering 145(3):031005. DOI:10.1115/1.4056291

Sadat N, Lojenburg JH, Scharfschwerdt M, Fujta B, Ensminger S (2023) Impact of different in vitro models on functional performance of the self-expanding transcatheter heart valve. European Journal of Cardio-Thoracic Surgery 64(4):ezad333. DOI:10.1093/ejcts/ezad333

International Organization for Standardization (2021) ISO 5840-3:2021 Cardiovascular implants - Cardiac valve prostheses - Part 3: Heart valve substitutes implanted by transcatheter techniques. ISO, Geneva.

Rotman OM, Kovarovic B, Bianchi M, Slepian MJ, Bluestein D (2020) In Vitro Durability and Stability Testing of a Novel Polymeric Transcatheter Aortic Valve. ASAIO Journal 66(2):190-198. DOI:10.1097/mat.0000000000000980

Sathananthan J, Hensey M, Landes U, Alkhodair A, Saiduddin A, Sellers S, Cheung A, Lauck S, Blanke P, Leipsic J, Ye J, Wood DA, Webb JG (2020) Long-Term Durability of Transcatheter Heart Valves: Insights From Bench Testing to 25 Years. JACC: Cardiovascular Interventions 13(2):235-249. DOI:10.1016/j.jcin.2019.07.049

Mehilli J (2020) Lessons Learned From In Vitro Durability Testing of Transcatheter Heart Valves. JACC: Cardiovascular Interventions 13(2):250-252. DOI:10.1016/j.jcin.2019.08.033

Stanová V, Rieu R, Thollon L, Salaun E, Rodés-Cabau J, Côté N, Mantovani D, Pibarot P (2024) Leaflet Mechanical Stress in Different Designs and Generations of Transcatheter Aortic Valves: An in Vitro Study. Structural Heart 8(2):100262. DOI:10.1016/j.shj.2023.100262

Sedaghat A, Sinning JM, Werner N, Nickenig G, Conradi L, Toggweiler S, Schäfer U (2018) In vitro hydrodynamic and acute clinical performance of a novel self-expanding transcatheter heart valve in various surgical bioprostheses. EuroIntervention 13(17):2014-2017. DOI:10.4244/EIJ-D-17-00844

Rahmani B, Tzamtzis S, Sheridan R, Mullen MJ, Yap J, Seifalian AM, Burriesci G (2017) In Vitro Hydrodynamic Assessment of a New Transcatheter Heart Valve Concept (the TRISKELE). Journal of Cardiovascular Translational Research 10(2):104-115. DOI:10.1007/s12265-016-9722-0

Tschorn P, Schröter F, Hartrumpf M, Kühnel RU, Ostovar R, Albes JM (2022) Engineering a New Polymeric Heart Valve Using 3D Printing-TRISKELION. Medicina 58(11):1695. DOI:10.3390/medicina58111695

Stasiak JR, Serrani M, Biral E, Taylor JV, Zaman AG, Jones S, Ness T, De Gaetano F, Costantino ML, Bruno VD, Suleiman S, Ascione R, Moggridge GD (2020) Design, development, testing at ISO standards and in vivo feasibility study of a novel polymeric heart valve prosthesis. Biomaterials Science 8(16):4467-4482. DOI:10.1039/D0BM00412J

Stanfield JR, Johnson G, Belais N, George I, Yakubov S (2026) Development and preclinical results of a transcatheter aortic valve implant with novel polymeric leaflets. npj Cardiovascular Health 3(1):14. DOI:10.1038/s44325-026-00112-x

Zhang BL, Bianco RW, Schoen FJ (2019) Preclinical Assessment of Cardiac Valve Substitutes: Current Status and Considerations for Engineered Tissue Heart Valves. Frontiers in Cardiovascular Medicine 6:72. DOI:10.3389/fcvm.2019.00072

Sathananthan J, Fraser R, Landes U, Rich C, Sellers SL, Leipsic J, Blanke P, Lutter G, Frank D, Puehler T, Wood DA, Søndergaard L, Webb JG (2021) Repeat transcatheter aortic valve implantation and implications for transcatheter heart valve performance: insights from bench testing. EuroIntervention 17(10):856-864. DOI:10.4244/EIJ-D-20-00697

Meier D, Delarive J, Lai A, Hahn RT, Cavalcante JL, Asgar AW, Latib A, Garg P, Kodali S, Bapat VN, Settergren M, Sathananthan J, Meduri CU, Sellers SL (2025) DurAVR - a novel biomimetic balloon-expandable transcatheter valve for TAVI, valve-in-valve TAVI and redo-TAVI. EuroIntervention 21(18):e1090-e1101. DOI:10.4244/EIJ-D-24-01000

Downloads

Published

2025-06-20