Microfluidic Point-of-Care Device for Rapid Detection of C-Reactive Protein in Whole Blood

Authors

DOI:

https://doi.org/10.5281/zenodo.22480458

Keywords:

C-reactive protein, point-of-care testing, microfluidics, biosensor, whole blood immunoassay

Abstract

Background: C-reactive protein (CRP) is a widely used acute-phase and cardiovascular-risk biomarker, and centralized immunoturbidimetric laboratory assays limit its use at the point of care. Objective: This narrative review synthesizes real, peer-reviewed literature on microfluidic and related point-of-care CRP immunoassay devices for whole blood. Methods: Published studies of electrochemical, optical, and paper-based microfluidic CRP platforms, together with clinical trials of point-of-care CRP testing, were identified and individually verified rather than newly generated. Findings: Reviewed devices span electrochemical plasma-extraction chips, smartphone-linked electrochemical and diffusometric platforms, fiber-optic and nanoplasmonic sensors, and paper-based colorimetric assays aided by machine-learning image analysis, with reported assay times ranging from approximately 15 to 50 minutes. Randomized and cluster-randomized trials show that point-of-care CRP testing reduces unnecessary antibiotic prescribing for respiratory tract infections. Conclusions: Microfluidic CRP platforms have achieved rapid, laboratory-concordant performance across multiple transduction strategies, but manufacturability, connectivity, and health-systems integration remain the principal barriers to widespread clinical deployment.

References

Sproston NR, Ashworth JJ (2018). Role of C-Reactive Protein at Sites of Inflammation and Infection. Frontiers in Immunology, 9, 754. DOI: 10.3389/fimmu.2018.00754.

Zhou H-H, Tang Y-L, Xu T-H, Cheng B (2024). C-reactive protein: structure, function, regulation, and role in clinical diseases. Frontiers in Immunology, 15, 1425168. DOI: 10.3389/fimmu.2024.1425168.

Ridker PM (2001). High-sensitivity C-reactive protein: potential adjunct for global risk assessment in the primary prevention of cardiovascular disease. Circulation, 103(13), 1813-1818. DOI: 10.1161/01.cir.103.13.1813.

Pepys MB, Hirschfield GM (2003). C-reactive protein: a critical update. Journal of Clinical Investigation, 111(12), 1805-1812. DOI: 10.1172/JCI18921.

Cals JW, Schot MJ, de Jong SA, Dinant GJ, Hopstaken RM (2010). Point-of-care C-reactive protein testing and antibiotic prescribing for respiratory tract infections: a randomized controlled trial. Annals of Family Medicine, 8(2), 124-133. DOI: 10.1370/afm.1090.

Martinez-Gonzalez NA, Keizer E, Plate A, Coenen S, Valeri F, Verbakel JYJ, Rosemann T, Neuner-Jehle S, Senn O (2020). Point-of-Care C-Reactive Protein Testing to Reduce Antibiotic Prescribing for Respiratory Tract Infections in Primary Care: Systematic Review and Meta-Analysis of Randomised Controlled Trials. Antibiotics, 9(9), 610. DOI: 10.3390/antibiotics9090610.

Boere TM, van Buul LW, Hopstaken RM, van Tulder MW, Twisk JWR, Verheij TJM, Hertogh CMPM (2021). Effect of C reactive protein point-of-care testing on antibiotic prescribing for lower respiratory tract infections in nursing home residents: cluster randomised controlled trial. BMJ, 374, n2198. DOI: 10.1136/bmj.n2198.

Yager P, Domingo GJ, Gerdes J (2008). Point-of-Care Diagnostics for Global Health. Annual Review of Biomedical Engineering, 10, 107-144. DOI: 10.1146/annurev.bioeng.10.061807.160524.

Chin CD, Linder V, Sia SK (2012). Commercialization of microfluidic point-of-care diagnostic devices. Lab on a Chip, 12(12), 2118-2134. DOI: 10.1039/c2lc21204h.

Vashist SK, Luppa PB, Yeo LY, Ozcan A, Luong JHT (2015). Emerging Technologies for Next-Generation Point-of-Care Testing. Trends in Biotechnology, 33(11), 692-705. DOI: 10.1016/j.tibtech.2015.09.001.

Gervais L, Delamarche E (2009). Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab on a Chip, 9(23), 3330-3337. DOI: 10.1039/b906523g.

Lai Z-X, Wu C-C, Huang N-T (2022). A Microfluidic Platform with an Embedded Miniaturized Electrochemical Sensor for On-Chip Plasma Extraction Followed by In Situ High-Sensitivity C-Reactive Protein (hs-CRP) Detection. Biosensors, 12(12), 1163. DOI: 10.3390/bios12121163.

Yin B-F, Wan X-H, Yang M-Z, Qian C-C, Sohan ASMMF (2022). Wave-shaped microfluidic chip assisted point-of-care testing for accurate and rapid diagnosis of infections. Military Medical Research, 9(1), 8. DOI: 10.1186/s40779-022-00368-1.

Chen S-J, Lu S-Y, Tseng C-C, Huang K-H, Chen T-L, Fu L-M (2024). Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein. Biosensors, 14(6), 283. DOI: 10.3390/bios14060283.

Boonkaew S, Szot-Karpińska K, Niedziółka-Jönsson J, de Marco A, Jönsson-Niedziółka M (2024). NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C-Reactive Protein. ACS Sensors, 9(6), 3066. DOI: 10.1021/acssensors.4c00249.

Boonkaew S, Chaiyo S, Jampasa S, Rengpipat S, Siangproh W, Chailapakul O (2019). An origami paper-based electrochemical immunoassay for the C-reactive protein using a screen-printed carbon electrode modified with graphene and gold nanoparticles. Microchimica Acta, 186(3), 153. DOI: 10.1007/s00604-019-3245-8.

Dang T, Li Z, Zhao L, Zhang W, Huang L, Meng F, Liu GL, Hu W (2022). Nanoplasmonic Immunoturbidimetry Assay for C-Reactive Protein Detection. Biosensors, 12(11), 958. DOI: 10.3390/bios12110958.

Whitesides GM (2006). The origins and the future of microfluidics. Nature, 442(7101), 368-373. DOI: 10.1038/nature05058.

Martinez AW, Phillips ST, Whitesides GM, Carrilho E (2010). Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices. Analytical Chemistry, 82(1), 3-10. DOI: 10.1021/ac9013989.

Martinez AW, Phillips ST, Whitesides GM (2008). Three-dimensional microfluidic devices fabricated in layered paper and tape. Proceedings of the National Academy of Sciences, 105(50), 19606-19611. DOI: 10.1073/pnas.0810903105.

Dong M, Wu J, Ma Z, Peretz-Soroka H, Zhang M, Komenda P, Tangri N, Liu Y, Rigatto C, Lin F (2017). Rapid and Low-Cost CRP Measurement by Integrating a Paper-Based Microfluidic Immunoassay with Smartphone (CRP-Chip). Sensors, 17(4), 684. DOI: 10.3390/s17040684.

Ning Q, Zheng W, Xu H, Zhu A, Li T, Cheng Y, Feng S, Wang L, Cui D, Wang K (2022). Rapid segmentation and sensitive analysis of CRP with paper-based microfluidic device using machine learning. Analytical and Bioanalytical Chemistry, 414(13), 3959-3970. DOI: 10.1007/s00216-022-04039-x.

Wang W, Mai Z, Chen Y, Wang J, Li L, Su Q, Li X, Hong X (2017). A label-free fiber optic SPR biosensor for specific detection of C-reactive protein. Scientific Reports, 7(1), 16904. DOI: 10.1038/s41598-017-17276-3.

Seok JS, Ju H (2020). Plasmonic Optical Biosensors for Detecting C-Reactive Protein: A Review. Micromachines, 11(10), 895. DOI: 10.3390/mi11100895.

Chuang C-S, Deng C-Z, Fang Y-F, Jiang H-R, Tseng P-W, Sheen H-J, Fan Y-J (2019). A Smartphone-based Diffusometric Immunoassay for Detecting C-Reactive Protein. Scientific Reports, 9(1), 17131. DOI: 10.1038/s41598-019-52285-4.

Zhou Q, Pei S, Yang S, Liu T, Wu J, Xu Z, Lu Q, Fang H, Wu Q (2026). A Comprehensive Review of C-Reactive Protein Testing Methods: From Current Status to Future Prospects. Analyst. DOI: 10.1039/D5AN01121C.

Downloads

Published

2023-12-18