Development of an Implantable Biosensor for Real-Time Lactate Monitoring in Critically Ill Patients
DOI:
https://doi.org/10.5281/zenodo.22642628Keywords:
implantable lactate biosensor, continuous lactate monitoring, critically ill patients, microneedle biosensor, sepsis resuscitation monitoringAbstract
Background: Blood lactate is a well-established marker of tissue hypoperfusion and a validated resuscitation target in sepsis and septic shock, yet routine intensive care unit (ICU) practice still relies on intermittent arterial or venous blood gas sampling, leaving the dynamic, minute-to-minute behavior of lactate largely unobserved between draws. Objective: This narrative review synthesizes published literature on implantable and minimally invasive biosensors developed to enable continuous, real-time lactate monitoring in critically ill patients. Methods: We reviewed clinical, engineering, and physiological studies spanning the prognostic rationale for continuous lactate monitoring, enzymatic amperometric lactate oxidase sensor chemistry, and device architectures including percutaneous microneedle arrays, subcutaneous and intravenous catheter-based sensors, intravascular microdialysis, and fully bioresorbable deep-tissue implants. Findings: Trial-level evidence confirms that acting on serial lactate measurements improves survival in sepsis, and subcutaneous tissue lactate clearance has been shown to predict ICU non-survival independently of blood lactate. Intravascular microdialysis and intravenous catheter sensors currently achieve the closest agreement with arterial blood gas reference measurements and the fastest response times, while microneedle and bioresorbable platforms offer progressively less invasive alternatives that have been validated chiefly in animal models, with at least one microneedle-based system now evaluated directly in critically ill ICU patients. Conclusions: Continuous implantable lactate biosensors have progressed from proof-of-concept transducers to platforms undergoing early clinical evaluation in the ICU, and maturing wireless telemetry and multiplexed biomarker integration may position them as standard components of real-time metabolic monitoring in critical care.
References
Broder G, Weil MH (1964) Excess Lactate: An Index of Reversibility of Shock in Human Patients. Science, 143(3613):1457-1459, DOI:10.1126/science.143.3613.1457.
Singer M, Deutschman CS, Seymour CW, Shankar-Hari M, Annane D, Bauer M, Bellomo R, Bernard GR, Chiche JD, Coopersmith CM, Hotchkiss RS, Levy MM, Marshall JC, Martin GS, Opal SM, Rubenfeld GD, van der Poll T, Vincent JL, Angus DC (2016) The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3). JAMA, 315(8):801-810, DOI:10.1001/jama.2016.0287.
Nguyen HB, Rivers EP, Knoblich BP, Jacobsen G, Muzzin A, Ressler JA, Tomlanovich MC (2004) Early lactate clearance is associated with improved outcome in severe sepsis and septic shock. Critical Care Medicine, 32(8):1637-1642, DOI:10.1097/01.ccm.0000132904.35713.a7.
Jansen TC, van Bommel J, Schoonderbeek FJ, Sleeswijk Visser SJ, van der Klooster JM, Lima AP, Willemsen SP, Bakker J (2010) Early lactate-guided therapy in intensive care unit patients: a multicenter, open-label, randomized controlled trial. American Journal of Respiratory and Critical Care Medicine, 182(6):752-761, DOI:10.1164/rccm.200912-1918OC.
Vincent JL, Quintairos e Silva A, Couto L Jr, Taccone FS (2016) The value of blood lactate kinetics in critically ill patients: a systematic review. Critical Care, 20:257, DOI:10.1186/s13054-016-1403-5.
Ilias I, Apollonatou S, Vassiliadi DA, Nikitas N, Theodorakopoulou M, Diamantakis A, Kotanidou A, Dimopoulou I (2018) Adipose Tissue Lactate Clearance but Not Blood Lactate Clearance Is Associated with Clinical Outcome in Sepsis or Septic Shock during the Post-Resuscitation Period. Metabolites, 8(2):28, DOI:10.3390/metabo8020028.
Ding Y, Yang L, Wen J, Ma Y, Dai G, Mo F, Wang J (2025) A Comprehensive Review of Advanced Lactate Biosensor Materials, Methods, and Applications in Modern Healthcare. Sensors, 25(4):1045, DOI:10.3390/s25041045.
Lafuente JL, Gonzalez S, Aibar C, Rivera D, Aviles E, Beunza JJ (2024) Continuous and Non-Invasive Lactate Monitoring Techniques in Critical Care Patients. Biosensors, 14(3):148, DOI:10.3390/bios14030148.
Gao W, Emaminejad S, Nyein HYY, Challa S, Chen K, Peck A, Fahad HM, Ota H, Shiraki H, Kiriya D, Lien DH, Brooks GA, Davis RW, Javey A (2016) Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature, 529(7587):509-514, DOI:10.1038/nature16521.
Jia W, Bandodkar AJ, Valdes-Ramirez G, Windmiller JR, Yang Z, Ramirez J, Chan G, Wang J (2013) Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration. Analytical Chemistry, 85(14):6553-6560, DOI:10.1021/ac401573r.
Wang Y, Vaddiraju S, Gu B, Papadimitrakopoulos F, Burgess DJ (2015) Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size. Journal of Diabetes Science and Technology, 9(5):966-977, DOI:10.1177/1932296815601869.
Nandhakumar P, Kim G, Sandhu SS, Reynoso M, Khan MI, Raucci A, He X, Acot B, Park R, Surace S, Kim GE, Wang J (2025) Rapid and Continuous Simultaneous Monitoring of Interleukin-6 and Lactate Using a Bioelectronic Sensor Platform: toward Early Sepsis Prediction. Analytical Chemistry, 97(33):18273-18281, DOI:10.1021/acs.analchem.5c03473.
Chien MN, Fan SH, Huang CH, Wu CC, Huang JT (2022) Continuous Lactate Monitoring System Based on Percutaneous Microneedle Array. Sensors, 22(4):1468, DOI:10.3390/s22041468.
Wang Q, Molinero-Fernandez A, Wei Q, Xuan X, Konradsson-Geuken A, Cuartero M, Crespo GA (2024) Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy. ACS Sensors, 9(6):3115-3125, DOI:10.1021/acssensors.4c00337.
Wolf A, Renehan K, Ho KKY, Carr BD, Chen CV, Cornell MS, Ye M, Rojas-Pena A, Chen H (2018) Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously. Biosensors, 8(4):122, DOI:10.3390/bios8040122.
Schierenbeck F, Nijsten MWN, Franco-Cereceda A, Liska J (2014) Introducing intravascular microdialysis for continuous lactate monitoring in patients undergoing cardiac surgery: a prospective observational study. Critical Care, 18(2):R56, DOI:10.1186/cc13808.
Hu C, Liang R, Li P, Ma Y, Xie Y, Liu S, Wang L, Peng M, Shen B, Ren X, Wang Z, Wu L, Li S, Mi Z, Peng X, Wang S, Dong Y, Jia Z, Xu W, Xiao M, Liu L, Wang Z, Qi H, Tian L, Ding H, Li R, Wang S, Fu W, Sheng X, Su W, Zhang M, Peng J, Jin X, Li B, Yin L (2026) Bioresorbable electrochemical sensors for continuous deep-tissue lactate monitoring in critical care. Nature Communications, 17:7366, DOI:10.1038/s41467-026-74248-w.
Djassemi O, Chang AY, McGuire WC, Mitchell E, Saha T, Fernandes T, Yang J, Miller M, Wurster C, Morales-Fermin S, McGregor I, Castillo-Valdovinos J, Malhotra A, Wang J (2026) Clinical Evaluation of Microneedle Biosensors for Continuous Lactate Monitoring in Critically Ill Patients. ACS Sensors, 11(2):1413-1424, DOI:10.1021/acssensors.5c03699.
Cai H, He Y, Wang C, Zhao Y, Yang C (2026) Beyond glucose: wearable and implantable biosensors for continuous monitoring of metabolic, hormonal, and inflammatory biomarkers in personalized cardiometabolic care. Frontiers in Bioengineering and Biotechnology, 14:1885022, DOI:10.3389/fbioe.2026.1885022.
Kim H, Rigo B, Wong G, Lee YJ, Yeo WH (2024) Advances in Wireless, Batteryless, Implantable Electronics for Real-Time, Continuous Physiological Monitoring. Nano-Micro Letters, 16(1):52, DOI:10.1007/s40820-023-01272-6.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Soren Riis, et al.

This work is licensed under a Creative Commons Attribution 4.0 International License.