Wearable Photoplethysmography Sensor for Continuous Heart Rate Monitoring: Validation Against Clinical ECG

Authors

DOI:

https://doi.org/10.5281/zenodo.22479974

Keywords:

photoplethysmography, wearable sensors, heart rate monitoring, electrocardiography validation, motion artifact

Abstract

Background: Wrist-worn photoplethysmography (PPG) is the dominant consumer method for continuous heart rate (HR) tracking, but agreement with clinical electrocardiography (ECG) varies with activity, device, and population. Objective: This narrative review synthesizes published validation studies comparing wearable PPG heart rate against simultaneous clinical-grade ECG. Methods: Peer-reviewed studies of consumer and research-grade PPG devices (Apple Watch, Fitbit, Garmin, Polar, and others) validated against ECG were organized around accuracy, motion artifact, and skin-tone bias. Findings: Devices agree closely with ECG at rest (Apple Watch median error 2.0%; concordance up to 0.96) but accuracy degrades during vigorous exercise and in cardiac patients; motion-artifact algorithms such as TROIKA reduce error to about 2.34 bpm during intense exercise; darker skin pigmentation is associated with larger errors (up to 16.5 bpm versus 3.5 bpm in lighter skin during high-intensity exercise). Conclusions: Wearable PPG is useful for screening and trend monitoring but is not a diagnostic substitute for ECG, particularly during exertion or in individuals with darker skin tones, underscoring the need for activity- and demographic-stratified validation.

References

Allen J (2007). Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 28(3), R1-R39. DOI: 10.1088/0967-3334/28/3/R01.

Tamura T, Maeda Y, Sekine M, Yoshida M (2014). Wearable Photoplethysmographic Sensors—Past and Present. Electronics, 3(2), 282-302. DOI: 10.3390/electronics3020282.

Perez MV, Mahaffey KW, Hedlin H, Rumsfeld JS, Garcia A, Ferris T, Balasubramanian V, Russo AM, Rajmane A, Cheung L, Hung G, Lee J, Kowey P, Talati N, Nag D, Gummidipundi SE, Beatty A, Hills MT, Desai S, Granger CB, Desai M, Turakhia MP (2019). Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation. New England Journal of Medicine, 381(20), 1909-1917. DOI: 10.1056/NEJMoa1901183.

Bent B, Goldstein BA, Kibbe WA, Dunn JP (2020). Investigating sources of inaccuracy in wearable optical heart rate sensors. npj Digital Medicine, 3, 18. DOI: 10.1038/s41746-020-0226-6.

Castaneda D, Esparza A, Ghamari M, Soltanpur C, Nazeran H (2018). A review on wearable photoplethysmography sensors and their potential future applications in health care. International Journal of Biosensors & Bioelectronics, 4(4), 195-202. DOI: 10.15406/ijbsbe.2018.04.00125.

Nelson BW, Allen NB (2019). Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study. JMIR mHealth and uHealth, 7(3), e10828. DOI: 10.2196/10828.

Shcherbina A, Mattsson CM, Waggott D, Salisbury H, Christle JW, Hastie T, Wheeler MT, Ashley EA (2017). Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort. Journal of Personalized Medicine, 7(2), 3. DOI: 10.3390/jpm7020003.

Pasadyn SR, Soudan M, Gillinov M, Houghtaling P, Phelan D, Gillinov N, Bittel B, Desai MY (2019). Accuracy of commercially available heart rate monitors in athletes: a prospective study. Cardiovascular Diagnosis and Therapy, 9(4), 379-385. DOI: 10.21037/cdt.2019.06.05.

Hettiarachchi IT, Hanoun S, Nahavandi D, Nahavandi S (2019). Validation of Polar OH1 optical heart rate sensor for moderate and high intensity physical activities. PLOS ONE, 14(5), e0217288. DOI: 10.1371/journal.pone.0217288.

Chow HW, Yang CC (2020). Accuracy of Optical Heart Rate Sensing Technology in Wearable Fitness Trackers for Young and Older Adults: Validation and Comparison Study. JMIR mHealth and uHealth, 8(4), e14707. DOI: 10.2196/14707.

Ceugniez M, Devanne H, Hermand E (2025). Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study. JMIR mHealth and uHealth, 13, e54871. DOI: 10.2196/54871.

Gagnon J, Khau M, Lavoie-Hudon L, Vachon F, Drapeau V, Tremblay S (2022). Comparing a Fitbit Wearable to an Electrocardiogram Gold Standard as a Measure of Heart Rate Under Psychological Stress: A Validation Study. JMIR Formative Research, 6(12), e37885. DOI: 10.2196/37885.

Higuchi D, Takahashi Y, Tanaka S, Tomita Y (2025). Validation of heart rate measured by the consumer-level wearable device Fitbit: a cross-sectional observational study. Journal of Physical Therapy Science, 37(11), 561-566. DOI: 10.1589/jpts.37.561.

Sartor F, Gelissen J, van Dinther R, Roovers D, Papini GB, Coppola G (2018). Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients. BMC Sports Science, Medicine and Rehabilitation, 10, 10. DOI: 10.1186/s13102-018-0098-0.

Seshadri DR, Bittel B, Browsky D, Houghtaling P, Drummond CK, Desai MY, Gillinov AM (2020). Accuracy of Apple Watch for Detection of Atrial Fibrillation. Circulation, 141(8), 702-703. DOI: 10.1161/circulationaha.119.044126.

Wasserlauf J, Vogel K, Whisler C, Benjamin E, Helm R, Steinhaus DA, Yousuf O, Passman RS (2023). Accuracy of the Apple watch for detection of AF: A multicenter experience. Journal of Cardiovascular Electrophysiology, 34(5), 1103-1107. DOI: 10.1111/jce.15892.

Schäfer A, Vagedes J (2013). How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram. International Journal of Cardiology, 166(1), 15-29. DOI: 10.1016/j.ijcard.2012.03.119.

Nelson BW, Low CA, Jacobson N, Areán P, Torous J, Allen NB (2020). Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research. npj Digital Medicine, 3, 90. DOI: 10.1038/s41746-020-0297-4.

Zhang Z, Pi Z, Liu B (2015). TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise. IEEE Transactions on Biomedical Engineering, 62(2), 522-531. DOI: 10.1109/TBME.2014.2359372.

Lee J, Kim M, Park HK, Kim IY (2020). Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths. Sensors, 20(5), 1493. DOI: 10.3390/s20051493.

Ismail S, Akram U, Siddiqi I (2021). Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review. EURASIP Journal on Advances in Signal Processing, 2021, 5. DOI: 10.1186/s13634-020-00714-2.

Koerber D, Khan S, Shamsheri T, Kirubarajan A, Mehta S (2023). Accuracy of Heart Rate Measurement Wrist-Worn Wearable Devices in Various Skin Tones: a Systematic Review. Journal of Racial and Ethnic Health Disparities, 10(6), 2676-2684. 10.1007/s40615-022-01446-9.

Hung SH, Serwa K, Rosenthal G, Eng JJ (2025). Validity of heart rate measurements in wrist-based monitors across skin tones during exercise. PLOS ONE, 20(2), e0318724. 10.1371/journal.pone.0318724.

Martin D, Johns C, Sorrell L, Healy E, Phull M, Olusanya S, Peters M, Fabes J (2024). Effect of skin tone on the accuracy of the estimation of arterial oxygen saturation by pulse oximetry: a systematic review. British Journal of Anaesthesia, 132(5), 945-956. DOI: 10.1016/j.bja.2024.01.023.

Singh S, Bennett MR, Chen C, Shin S, Ghanbari H, Nelson BW (2024). Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis. Journal of Medical Internet Research, 26(1), e62769. DOI: 10.2196/62769.

Hu S, Elsahar Y, Hou J, Dwyer VM (2026). Multispectral optoelectronic sensor to detect peripheral blood pulsatile variations with equivalent performance in light, medium and dark skin tones. Scientific Reports, 16, 1635. 10.1038/s41598-025-31116-9. with DOI: DOI: DOI:

Downloads

Published

2023-12-25